| Basic PDU | Distributes utility or UPS power to rack equipment without local measurement or remote switching. | Usually single-phase, with common nominal inputs of 120 V, 208 V, 220–240 V, or 230 V; current ratings commonly range from 10 A to 32 A depending on the market and connector system. | No built-in monitoring; protection may include a circuit breaker, fuse, or thermal overload device. | Small server rooms, low-density racks, and installations where power visibility is not required. | IEC 60320 for appliance couplers; IEC 61439-1 and IEC 61439-2 where the PDU is treated as a low-voltage switchgear and controlgear assembly; IEC 61000 series for EMC; IEC 60529 for enclosure protection where applicable. | Verify input plug, outlet type, voltage, current, short-circuit rating, conductor size, earthing method, and local certification requirements. |
| Metered-Input PDU | Measures the total electrical load entering the rack or power strip. | Single-phase or three-phase; common three-phase configurations include 230/400 V or 240/415 V systems, subject to regional power distribution practices. | Local display commonly provides voltage, current, frequency, apparent power, real power, power factor, and accumulated energy; remote communications may be optional. | Capacity planning, rack commissioning, overload prevention, and basic energy reporting. | IEC 60320; IEC 61439-1/-2 where applicable; IEC 61000-4 measurement and EMC-related requirements; IEC 62053 measurement-equipment requirements may be relevant when energy-meter accuracy is specified. | Compare measurement accuracy class, display resolution, phase-level visibility, alarm thresholds, calibration method, and whether readings are true-RMS. |
| Metered-Outlet PDU | Measures electrical consumption at individual outlets or outlet groups. | Typically single-phase or three-phase with outlet-level current limits determined by the branch circuit and connector rating. | Outlet-level voltage, current, power, energy, and power factor; communication is commonly available through Ethernet or a serial interface. | Colocation billing support, cabinet-level energy allocation, stranded-capacity analysis, and tenant reporting. | IEC 60320; IEC 61439-1/-2 where applicable; IEC 61000 series; IEC 62053 considerations for energy measurement; SNMPv3 and HTTPS/TLS for secure management where supported. | Check measurement accuracy at low loads, outlet naming, data-retention capacity, API support, time synchronization, and cybersecurity controls. |
| Switched PDU | Provides remote outlet switching for controlled power cycling and load sequencing. | Available in single-phase and three-phase versions; outlet switching may be individually controlled or arranged in groups. | Remote on/off control, outlet sequencing, current and voltage monitoring, user permissions, event logs, and configurable alarms. | Remote recovery of locked equipment, staged server startup, maintenance isolation, and prevention of simultaneous inrush current. | IEC 60320; IEC 61439-1/-2 where applicable; IEC 61000 series; IEC 62368-1 or the applicable national equivalent for ICT equipment safety; IEC 62443 principles may be used when evaluating industrial-style cybersecurity controls. | Require fail-safe behavior, local manual override, outlet switching endurance, boot-state configuration, dual-user authorization, and protection against accidental shutdown. |
| Automatic Transfer Switching PDU | Automatically transfers a connected load between two independent power sources when the preferred source fails or moves outside defined limits. | Usually single-phase for rack-level distribution; source ratings commonly match 120–240 V systems, with current capacity selected according to the protected load and upstream circuit. | Source voltage and frequency monitoring, transfer-status indication, source-priority settings, alarms, and optional remote communications. | Single-corded servers, network equipment, edge sites, and racks requiring source redundancy without dual power supplies in every device. | IEC 60947-6-1 for automatic transfer switching equipment where applicable; IEC 61439-1/-2 for assembly construction where applicable; IEC 60320; IEC 61000 series. | Compare transfer time, source synchronization requirements, break-before-make behavior, neutral switching, source isolation, withstand rating, and compatibility with UPS outputs. |
| High-Density Three-Phase PDU | Delivers higher rack power through three-phase distribution while balancing loads across phases. | Common nominal systems include 230/400 V and 240/415 V; input current may be configured from approximately 16 A to 63 A or higher, subject to installation design and local regulations. | Phase-level voltage, current, power, energy, power factor, phase imbalance, peak demand, and alarm status. | High-density compute, accelerated-computing racks, virtualization clusters, and modern cooling or power-intensive IT loads. | IEC 61439-1/-2; IEC 60320 where appliance couplers are used; IEC 61000 series; IEC 60529 where an IP rating is claimed; local low-voltage installation rules. | Compare phase-balance capability, neutral-current handling, harmonic effects, breaker coordination, heat rise, derating, cable flexibility, and rack power density. |
| Busway or Tap-Off PDU | Connects rack loads to an overhead or underfloor busway through removable tap-off units. | Commonly three-phase, with voltage and current selected according to the facility distribution system; tap-off ratings vary by installation design. | May include local or remote metering for each tap-off, branch protection, temperature monitoring, and circuit identification. | Modular data halls, rapidly changing rack layouts, high-density deployments, and facilities requiring scalable distribution. | IEC 61439-6 for busbar trunking systems; IEC 61439-1 for general assembly requirements; IEC 60320 where applicable; IEC 60529 and IEC 61000 series where relevant. | Evaluate tap-off interchangeability, mechanical keying, touch protection, fault containment, installation clearances, short-circuit withstand, and future expansion capacity. |